Describe the location of indoor fire hydrants

Describe the location of indoor fire hydrants

  • Categories:Company News
  • Author:
  • Origin:
  • Time of issue:2021-10-13
  • Views:

(Summary description)In addition to the obvious signs of indoor fire hydrants, its fire hose reels and portable water hoses should also be set with relatively obvious fixed signs. When indoor fire hydrants need to be installed concealed due to aesthetic requirements, there should be obvious signs and should be easy to open and use. The water outlet direction of the fire hydrant outlet should be downward or at a 90° angle to the wall on which the fire hydrant is set, and the hydrant outlet should not be installed on the side of the door shaft.

Describe the location of indoor fire hydrants

(Summary description)In addition to the obvious signs of indoor fire hydrants, its fire hose reels and portable water hoses should also be set with relatively obvious fixed signs. When indoor fire hydrants need to be installed concealed due to aesthetic requirements, there should be obvious signs and should be easy to open and use. The water outlet direction of the fire hydrant outlet should be downward or at a 90° angle to the wall on which the fire hydrant is set, and the hydrant outlet should not be installed on the side of the door shaft.

  • Categories:Company News
  • Author:
  • Origin:
  • Time of issue:2021-10-13 17:53
  • Views:
Information

In addition to the obvious signs of indoor fire hydrants, its fire hose reels and portable water hoses should also be set with relatively obvious fixed signs. When indoor fire hydrants need to be installed concealed due to aesthetic requirements, there should be obvious signs and should be easy to open and use. The water outlet direction of the fire hydrant outlet should be downward or at a 90° angle to the wall on which the fire hydrant is set, and the hydrant outlet should not be installed on the side of the door shaft.

The location of the fire hydrant in the building shall meet the requirements of fire fighting and shall meet the following requirements:

1. Indoor fire hydrants should be located in the stairwell and its rest platform, front room, aisle, etc., which are clearly accessible and convenient for fire fighting.

2. The indoor fire hydrant of the residence should be set in the stairwell and its rest platform.

3. The setting of fire hydrants in the garage should not affect the passage of cars and the setting of parking spaces, and the opening of fire hydrants should be ensured.

4. Fire hydrants set in the same stairwell and on different floors nearby should have the same plane position.

5. The indoor bolt of the cold storage should be set in the hall or stairwell at room temperature.

Indoor fire hydrant is a relatively important fire-fighting equipment. Generally, when it is equipped with automatic sprinkler system, water spray fire-extinguishing system, foam fire-extinguishing system or fixed fire monitor fire-extinguishing system, one or more automatic water fire-extinguishing systems are fully integrated. During protection, when the height of a high-rise building is not higher than 50m and the design flow rate of the indoor hydrant system is higher than 20L/s, the design flow rate of the indoor hydrant system can be reduced by 5L/s according to the regulations; the design flow rate of the indoor hydrant system in multi-storey buildings can be reduced by 50% But it should not be less than 10L/s.

Keyword:

Scan the QR code to read on your phone

Related News

[Heavyweight] Emergency Management Department: The draft of the "Regulations on the Supervision and Administration of Fire Products" is out!
2021 07-16

[Heavyweight] Emergency Management Department: The draft of the "Regulations on the Supervision and Administration of Fire Products" is out!

Notice on the public solicitation of opinions on the "Provisions on the Quality Supervision and Administration of Fire Products (Revised Draft for Comments)"
Hard core test: fire test comparison with automatic sprinkler system vs without automatic sprinkler system
2021 02-19

Hard core test: fire test comparison with automatic sprinkler system vs without automatic sprinkler system

Installation of automatic sprinklers VS places without automatic sprinklers
29 dead in Quanzhou Xinjia hotel collapse
2021 01-24

29 dead in Quanzhou Xinjia hotel collapse

On March 7, 2020, the Quanzhou Xinjia Hotel, which was used for centralized isolation, collapsed. At the time of the incident, a total of 71 people were trapped in the building, most of whom came to Quanzhou from other places for centralized isolation and health observation. After rescue, 42 people were trapped in the building. One person survived, and 29 others unfortunately died.

Maybe you also want to know

搜索
Search

Online message

Username used for comment:
客户留言
Description:
Verification code
Copyright © 2022 Baisha Fire-fighting Equipment Co,Ltd All Right Reserved.